FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource Requirements/FHIR Server from package hl7.ehrs.ehrsfmr21#current (31 ms)

Package hl7.ehrs.ehrsfmr21
Type Requirements
Id Id
FHIR Version R5
Source http://hl7.org/ehrs/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2.1-RI.1.1.26.1.html
Url http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.26.1
Version 2.1.0
Status active
Date 2024-11-26T16:30:50+00:00
Name RI_1_1_26_1_Evidence_of_Record_Entry_Encryption_Event
Title RI.1.1.26.1 Evidence of Record Entry Encryption Event (Function)
Experimental False
Realm uv
Authority hl7
Description Maintain Evidence of Record Entry Encryption Event
Purpose Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Maintain Evidence of Record Entry Encryption Event

Description I:

Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit.

Criteria N:
RI.1.1.26.1#01 SHALL

The system SHALL audit each occurrence when Record Entry content is encrypted.

RI.1.1.26.1#02 SHALL

The system SHALL capture identity of the organization where Record Entry content is encrypted.

RI.1.1.26.1#03 SHALL

The system SHALL capture identity of the patient who is subject of encrypted Record Entry content.

RI.1.1.26.1#04 SHALL

IF a user initiated a Record Entry content encryption, THEN the system SHALL capture identity of the user initiating Record Entry content encryption.

RI.1.1.26.1#05 SHALL

The system SHALL capture identity of the system application which encrypted Record Entry content.

RI.1.1.26.1#06 SHALL

The system SHALL capture the type of Record Event trigger (i.e., encryption).

RI.1.1.26.1#07 SHALL

The system SHALL capture the date and time Record Entry content is encrypted.

RI.1.1.26.1#08 SHALL

The system SHALL capture identity of the location (i.e., network address) where Record Entry content is encrypted.

RI.1.1.26.1#09 MAY

IF a user initiated a Record Entry encryption, THEN the system MAY capture the rationale for encrypting Record Entry content.

RI.1.1.26.1#10 SHALL

The system SHALL capture a sequence identifier for encrypted Record Entry content.

RI.1.1.26.1#11 SHOULD

The system SHOULD capture the identifier and version of Encryption Tools used for each encrypted Record Entry.

RI.1.1.26.1#12 SHOULD

The system SHOULD capture a reference (e.g., link, pointer) to pre-encrypted data for each Record Entry encryption.


Source

{
  "resourceType" : "Requirements",
  "id" : "EHRSFMR2.1-RI.1.1.26.1",
  "meta" : {
    "profile" : [
      "http://hl7.org/ehrs/StructureDefinition/FMFunction"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Maintain Evidence of Record Entry Encryption Event</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL audit each occurrence when Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the organization where Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the patient who is subject of encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a user initiated a Record Entry content encryption, THEN the system SHALL capture identity of the user initiating Record Entry content encryption.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the system application which encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture the type of Record Event trigger (i.e., encryption).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture the date and time Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#08</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the location (i.e., network address) where Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#09</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>MAY</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a user initiated a Record Entry encryption, THEN the system MAY capture the rationale for encrypting Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#10</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture a sequence identifier for encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#11</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD capture the identifier and version of Encryption Tools used for each encrypted Record Entry.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#12</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD capture a reference (e.g., link, pointer) to pre-encrypted data for each Record Entry encryption.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
  },
  "url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.26.1",
  "version" : "2.1.0",
  "name" : "RI_1_1_26_1_Evidence_of_Record_Entry_Encryption_Event",
  "title" : "RI.1.1.26.1 Evidence of Record Entry Encryption Event (Function)",
  "status" : "active",
  "date" : "2024-11-26T16:30:50+00:00",
  "publisher" : "EHR WG",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description" : "Maintain Evidence of Record Entry Encryption Event",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "purpose" : "Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit.",
  "statement" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-01",
      "label" : "RI.1.1.26.1#01",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL audit each occurrence when Record Entry content is encrypted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-02",
      "label" : "RI.1.1.26.1#02",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the organization where Record Entry content is encrypted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-03",
      "label" : "RI.1.1.26.1#03",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the patient who is subject of encrypted Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-04",
      "label" : "RI.1.1.26.1#04",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "IF a user initiated a Record Entry content encryption, THEN the system SHALL capture identity of the user initiating Record Entry content encryption."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-05",
      "label" : "RI.1.1.26.1#05",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the system application which encrypted Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-06",
      "label" : "RI.1.1.26.1#06",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the type of Record Event trigger (i.e., encryption)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-07",
      "label" : "RI.1.1.26.1#07",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the date and time Record Entry content is encrypted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-08",
      "label" : "RI.1.1.26.1#08",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the location (i.e., network address) where Record Entry content is encrypted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-09",
      "label" : "RI.1.1.26.1#09",
      "conformance" : [
        "MAY"
      ],
      "conditionality" : false,
      "requirement" : "IF a user initiated a Record Entry encryption, THEN the system MAY capture the rationale for encrypting Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-10",
      "label" : "RI.1.1.26.1#10",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture a sequence identifier for encrypted Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-11",
      "label" : "RI.1.1.26.1#11",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD capture the identifier and version of Encryption Tools used for each encrypted Record Entry."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.26.1-12",
      "label" : "RI.1.1.26.1#12",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD capture a reference (e.g., link, pointer) to pre-encrypted data for each Record Entry encryption."
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.